<LOGO>
FM Transmitter Measurement Report
Created: 2024-10-30 09-03-30
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
107.20 MHz 4/5, 55 dBuV RMC
Pilot RDS Phase Difference
0.0 kHz 3.2 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
3 kHz 70 kHz 16779 0,0238
Modulation Power
Limit Measuring Tolerance
10,0 dBr 3,0 dBr
MIN AVE MAX % above 13,0 dBr
5,3 dBr 6,23 dBr 6,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RMC " F216 0 (No PTY) 1 0 1 2 9:03, 30.10.2024
RT
"RMC BLOIS 107.2 "
AF EON
90.1, 90.2, 93.7, 95.3, 96.5, 96.8, 99.6, 100.7, 101.2, 101.6, 103.1, 103.2, 103.7, 103.9, 107.2, 107.3, 107.5 MHz -
FM Scope Station: 107.20 MHz, signal: 4/5 (55 dBuV) Max at: 70 kHz MIN: 3 kHz % above 75 kHz: 0,0238 Acquired: 2024/10/30 9:02:26 Total samples: 16779 Equivalent time: 0:13:58 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 6,7 dBr MIN: 5,3 dBr AVE: 6,23 dBr % above 13,0 dBr: 0,0 Last value: 6,2 dBr (2024/10/30 9:02:24) Station: 107.20 MHz, signal: 4/5 (55 dBuV) 08:50 08:52 08:54 08:56 08:58 09:00 09:02 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality